Recovery coil TLFL

Aircoil’s fluid-linked recovery system, type TLFL

The TLFL recovery coil is used for heating supply air and cooling extract air. Ideal for installing in ducts with a guide or flange connection, or for embedding in a unit.

  • Copper headers with plugged outlets for aeration and discharge (1/8″).
  • Connections on the fluid side with external pipe threads up to and including DN 80.  The connection dimensions are stated in the technical calculation.
  • The coils are labelled to indicate the inflow and outflow, respectively, on the fluid side, as well as the air direction. 

The extract air coils type are fitted with a drip tray that is available with vertical or horizontal draining. 

Type IA can be supplied with or without a drip tray. The type A, B and C models can all be equipped with either a Guide (G) or Flange (F).

In order to ensure an optimal counter-flow-connected circuit, these coils are not drainable. 

Aircoil - Värmeväxlare - återvinningsbatteri TLFL
TL & FL MODELS ARE AVAILABLE IN FOUR VERSIONS
Återvinningsbatteri TLFL - typ TL A

Type TL A

Open ends with visible headers and tube bends outside the connection dimensions.

Återvinningsbatteri TLFL - typ TL B

Type TL B

Covered ends with capped headers and tube bends outside the connection dimensions.

Återvinningsbatteri TLFL - typ TL C

Type TL C

Covered ends with capped headers and tube bends inside the connection dimensions.

Återvinningsbatteri TLFL - typ TL iA

Type TL IA

Inside the unit, adapted with millimetre precision to the interior width and height of the unit.

Återvinningsbatteri TLFL - typ FL A

Type FL A

Open ends with visible headers and tube bends outside the connection dimensions.

Återvinningsbatteri TLFL - typ FL B

Type FL B

Covered ends with capped headers and tube bends outside the connection dimensions.

Återvinningsbatteri TLFL - typ FL C

Type FL C

Covered ends with capped headers and tube bends inside the connection dimensions.

Återvinningsbatteri TLFL - typ FL iA

Type FL IA

Inside the unit, adapted with millimetre precision to the interior width and height of the unit.

Standard model

As standard the coils are supplied labelled in accordance with AMA VVS & KYL 16. Installation instructions for connecting the coil and the drip tray are supplied with the coils. The following materials are used in the standard version:

  • Copper tubes
  • Aluminium fins
  • Hot galvanised sheet steel casing

Many other materials are available and can be machined to match specific wishes and requirements.

  • Max. working pressure 16 Bar
  • Max. working temperature 110 ˚C
  • Type A och B Tightness Class B
  • Type C Tightness Class C
Scroll to Top